查看完整版本: CAT6500自动电源选择开关详细介绍

admin 发表于 2014-10-11 07:57:02

CAT6500自动电源选择开关详细介绍

        CAT6500 is an automatic power switch designed to select between two power sources and direct that power to a load for battery charging or system power.
       
        CAT6500’s power inputs withstand voltages of up to 18 V and protect the downstream load from voltages exceeding 7V. In the event of a polarity reversal at either input CAT6500’s internal power switches will shut off to prevent discharge of the system’s internal power source.
       
        功能框图:
       
        CAT6500功能框图
       
        管脚定义:
       
       
        CAT6500管脚定义
       
        引脚功能描述:
       
                                                                                                                        Pin No.
                                                                                                                        Pin Name
                                                                                                                        Description
                                                                                                                       
                                                                                                                                                        1, 2, 3, 4
                                                                                                                        PWR_OUT
                                                                                                                        Power Output. Must be tied to PWR_OUT on opposite side of chip. Use all 3 pins each side.
                                                                                                                       
                                                                                                                                                        5
                                                                                                                        NIC
                                                                                                                        No Internal Connection. A signal or voltage applied to this pin will have no effect on device operation.
                                                                                                                       
                                                                                                                                                        6, 7, 8, 9, 10
                                                                                                                        PS2
                                                                                                                        Power Source #2. External power input
                                                                                                                       
                                                                                                                                                        11, 12
                                                                                                                        NIC
                                                                                                                        No Internal Connection. A signal or voltage applied to this pin will have no effect on device operation.
                                                                                                                       
                                                                                                                                                        13
                                                                                                                        VCC
                                                                                                                        Power input from battery.
                                                                                                                       
                                                                                                                                                        14
                                                                                                                        GND
                                                                                                                        Ground. Reference point for all voltages.
                                                                                                                       
                                                                                                                                                        15
                                                                                                                        C1
                                                                                                                        Filter capacitor for CAT6500’s internal power bus
                                                                                                                       
                                                                                                                                                        16
                                                                                                                        NIC
                                                                                                                        No Internal Connection. A signal or voltage applied to this pin will have no effect on device operation.
                                                                                                                       
                                                                                                                                                        17
                                                                                                                        NIC
                                                                                                                        No Internal Connection. A signal or voltage applied to this pin will have no effect on device operation.
                                                                                                                       
                                                                                                                                                        18
                                                                                                                        PRIORITY
                                                                                                                        Priority selects preferred power source when both PS1 and PS2 are powered.
                                                                                                                       
                                                                                                                                                        19
                                                                                                                        RM_EN2
                                                                                                                        Reverse Mode Enable 2. Overrides PRIORITY and turns SW2 ON.
                                                                                                                       
                                                                                                                                                        20
                                                                                                                        GND
                                                                                                                        Ground. Reference point for all voltages.
                                                                                                                       
                                                                                                                                                        21
                                                                                                                        RM_EN1
                                                                                                                        Reverse Mode Enable 1. Overrides PRIORITY and turns SW1 ON.
                                                                                                                       
                                                                                                                                                        22
                                                                                                                        PS1
                                                                                                                        Power Source #1. External power input.
                                                                                                                       
                                                                                                                                                        23
                                                                                                                       
                                                                        SW2_STAT
                                                                                                                        Power Source 2 Status. An open drain LOW true logic level output indicating that the switch SW2 is
                                                                                                                       
                                                                                                                                                       
                                                                                                                                                        24
                                                                                                                       
                                                                        SW1_STAT
                                                                                                                        Power Source 1 Status. An open drain LOW true logic level output indicating that the switch SW1 is
                                                                                                                       
                                                                                                                                                       
                                                                                                                                                        25, 26, 27, 28
                                                                                                                        PS1
                                                                                                                        Power Source #1. External power input.
                                                                                                                       
                                                                                                                                                        29
                                                                                                                        NIC
                                                                                                                        No Internal Connection. A signal or voltage applied to this pin will have no effect on device operation.
                                                                                                                       
                                                                                                                                                        30, 31, 32
                                                                                                                        PWR_OUT
                                                                                                                        Power Output. Must be tied to PWR_OUT on opposite side of chip. Use all 3 pins each side.
                                                                                                                       
                                                                                                                                                        33
                                                                                                                        PWR_OUT
                                                                                                                        Electrically active thermal pad. Does not need to be connected to other PWR_OUTs. Can be left float-ing but must not be connected to other signal paths or Ground.
                                                                                                                       
                                                                                                                                                        34
                                                                                                                        PS2
                                                                                                                        Electrically active thermal pad. Does not need to be connected to other PS2 pins. Can be left floating but must not be connected to other signal paths or Ground.
                                                                                                                       
                                                                                                                                                        35
                                                                                                                        –
                                                                                                                        Mechanical support for control IC. This chip does not generate any significant heat and does not need a separate heat sinking connection. Electrically this may be left floating or can be grounded. It should NOT be connected to other signals or voltages.
                                                                                                                       
                                                                                                                                                        36
                                                                                                                        PS1
                                                                                                                        Electrically active thermal pad. Does not need to be connected to other PS1 pins. Can be left floating but must not be connected to other signal paths or Ground.
                                                                                                                       
                                                       